Operation and Maintenance Manual
Reason | Solution | |
---|---|---|
Reason 1. Power not connected or phase loss 2. Circirt braker is triggered |
Solution 1. Please double check all switches are opened. 2. Check braker. If braker still trigger after reset (Figure 2), please contact supplier. |
Reason | Solution | |
---|---|---|
Reason 1. Inverter alarm 2. Inverter broke |
Solution 1. Please check inverterpane. If no error code display,check power supply situation. If pane display error code,plese turn off Collector and turn on again 2. If error code can not solve,plaese check Shihlin SE3/SC3 inverter user manual,follow invertermanual instruction or contect supplier. |
Reason | Solution | |
---|---|---|
Reason 1. Electrode Plate dirty. 2. Electrode Plate broke |
Solution 1. Please confirm whether it is still flashing after turn on main switch again. If still flashing, turn off main power switch and take out the Electrode Plate. If electrode plate is dirty or short with metal filings.Clean Electrode Plate by pressurized air. According to the pressurized air use rules in the cleaning chapter 6.3.1, clean up the large pieces of residual material. 2. Please check electrode plate, if electrode plate broke or short, please contact supplier. |
Reason | Solution | |
---|---|---|
Reason 1. Electrode occasional error. 2. Related electronic parts failure |
Solution 1. Follow troubleshooting 6.2.3instruction to solve electrode error. 2. Please check operating light. If it isn’t work, please check fuse and change open one. In case Collector is still inefficient, please contact to supplier. |